DC/DC 600DC/24DC/2kW

DC/DC 600DC/24DC/2kW
Product details

24V 2kW DC/DC

The product is a lightweight and high efficiency rail transit product. Provide DC24V power supply for vehicles.

20250217      OCDD5D1IF660083X DCDC.png

Ch arleroi Trams


Composition

  • Input Grid-side Circuit

  • Primary power board

  • High frequency isolation transformer

  • Rectifier bridge

  • Output filtering circuit

  • Control board

Function Description

The product converts the DC600V into a DC24V output isolated from the input, and then supplies power to the back-end DC load.


Characteristics

  • High switching frequency(SIC, max 100kHz)

  • High efficiency

  • Small size and light weight

  • Easy maintenance


Technical Parameters

Input voltageDC600V
Input voltage rangeDC400~750V
Output voltageDC24V
Output power2kW
Isolation methodHigh frequency transformer
Efficiency≥92%
Protection levelIP66
Sizes771*293*262mm
Weight36kg
Communication mode

RS232 Maintenance

Ambient temperature-25℃~+45℃


20250217   20250217


Control and Monitoring

The product control board exchanges data with external controllers through I/O signals. The control board drives on/off the switch tube based on the control command transmitted by the external controller, while recording the status information of the converter cabinet and transmitting it to the external controller through I/O signals, in order to obtain the status of the product.


Cooling Method

The product comes with a cooling fan for forced air cooling.


Structural Design

The product adopts a flat roof installation, and the main material of the cabinet is aluminum alloy.The product is lightweight and easy to maintain on site.


Diagnosis and Maintenance

The product has RS232 maintenance interface and PTU maintenance software. By connecting to the PTU through a computer, the operation data and status of the converter can be monitored in real-time. At the same time, the PTU has specific fault diagnosis and fault recording functions. You can view the current fault status through PTU and download fault data to analyze and solve the problem.


Application Description

The product is used in batch on ALSTOM Charleroi Trams.

Address: The Core Power Industry Park, Changsha National Economic and Technical Technical Development Zone, Hunan, China
Email: ocetsales@occonverter.com Tel: +86-731-84013499 Fax: +86-731-84018466 After sales service hotline: 400-888-0225